Live-Cell Fluorescence Imaging Chip

CIC-6F

Six-channel microfluidic imaging chip can use with a 170 µm optical bottom for confocal fluorescence microscopy, live-cell observation, blood cells, and micro-volume samples operation.

Bring Small Samples into an Imaging-Ready Microchannel

Live-Cell Fluorescence Imaging Chip is a six-channel microfluidic observation chip developed for fluorescence and high-magnification microscopy. Samples remain inside defined microchannels, allowing researchers to work with small volumes while keeping cells or blood cells in an imaging-friendly format.

Fluorescence_Imaging_Chip_t1b.jpg

Optical Bottom Designed for Confocal Microscopy

The chip uses a 170 µm optical bottom, corresponding to the standard 0.17 mm coverslip thickness commonly used for high-resolution microscopy. This design supports confocal fluorescence microscopy and other high-magnification imaging workflows.

Six Independent Channels for Efficient Experimental Design

Each chip contains six short channels, allowing up to six independent experiments or conditions on a single slide-format device. Standard pipettes can be used to introduce cell suspensions or blood samples, making the chip easy to integrate into routine laboratory workflows.

Feature

  • Compatible with confocal fluorescence microscopy and high-magnification observation.

  • 170 µm optical bottom designed around standard microscopy optics.

  • Six independent microfluidic channels on one chip.

  • Supports observation, image capture, and video recording of rare or micro-volume samples.

  • Allows for real-time observation of cellular drug responses.

  • Supports live-cell and blood-cell observation and research.Use small sample volumes to help conserve cells and reagents.

  • Use small sample volumes to help conserve cells and reagents.

  • Samples are contained within microchannels rather than spread across a conventional flat slide.

  • Compatible with standard pipettes for introducing cell suspensions or blood samples.

  • Can be used for cell and microbial experiments within the microchannels.

Application

Fluorescence_microscopy_1.jpg
cell_research_1.jpg

Confocal Fluorescence Microscopy

Designed for high-resolution fluorescence imaging where optical compatibility and controlled sample placement are important.

live_Cell_1.jpg

Live-Cell and Blood-Cell Observation

Supports direct microscopic observation of live cells and blood cells, including image capture and video recording.

Laboratory_1.jpg

Microbial and Cell-Based Experiments

The channels can be used as a compact environment for cell or microorganism observation and other microscopy-centered experimental workflows.

cell_research_4.jpg

Micro-Volume and Precious Samples

The microchannel format helps reduce sample and reagent consumption, making it useful when cells or reagents are limited.

cell_sample_1.jpg

Real-Time Drug Responses

Enables the continuous monitoring of live-cell dynamic responses to drug treatments in real time.

Specification

Direction for Use

A general imaging workflow is provided below. Sample preparation, staining, incubation, and imaging conditions should be selected according to the experimental protocol.

​

  1. Prepare the cell suspension, blood sample, microorganism sample, or stained specimen according to the study protocol.

  2. Using a standard pipette, introduce the sample through the inlet and allow the microchannel to fill without trapping bubbles.

  3. Confirm that the sample is positioned in the observation region of the selected channel.

  4. Place Live-Cell Fluorescence Imaging Chip on the microscope stage and select the appropriate objective and imaging mode.

  5. For fluorescence experiments, use excitation, emission, exposure, and acquisition settings established for the fluorophore and microscope system.

  6. Capture images or video as required by the experiment.

  7. Use the remaining channels for additional replicates, conditions, or samples as appropriate.

  8. After completion, handle and dispose of the used chip according to the laboratory's biological-safety procedure.

Fluorescence_Imaging_Chip_usage_2.jpg

Note: Recommended loading volume and incubation conditions are protocol-dependent.

模糊的圖像

Related Products

Welcome Private Label, OEM/ODM, Distribution, and Agency Partnerships

For any further question ( Minimum Order Quantity, Prices or Domestic Distributor), please fill out the inquiry form, we will get back to you as soon as possible. Let us work together to make your product come true and hit the market successfully.

Aurum Biomedical Technology Inc.

Tel: +886-2-2502-2575
e-Mail: websales@aurumbio.com​
​Address: 10F-3, No.206, Sec. 2, Nanking E. Rd., Taipei City, Taiwan 

Copyright © 2018 Aurum Biomedical Technology Inc. All Rights Reserved.

bottom of page